Area of Use Main roads, service roads and collecting roads, squares, parking lots, residential areas and parks
Design Luminaire housing made of aluminum, mast connection via system-connected cantilever systems via installation-friendly cone attachment, electric block wired ready for connection, removable via keyholes, luminaire glass made of impact-resistant acrylic glass (PMMA), glass tilts down completely for lamp replacement via 2 three-quarter turn screw tops, color coating according to RAL or DB.
Optical System Reflector made of pure aluminum for an asymmetrical light intensity distribution, lying illuminant.
Specialties System-connected accessories (cantilever) required for mast installation.
Illuminants (max. power)
| CPO |
1× 45 - 90 Watt |
| HIT-CE |
1× 70 - 100 Watt |
| HIT-T |
1× 35 - 70 Watt |
| HSE/T |
1× 50 - 100 Watt |
| TC-TEL |
1× 26 - 57 Watt |
Specifications
| Weight |
ca. 8.5 kg |
| Nominal voltage |
230 Volt 50 Hz |
| Protection type |
IP 55 |
| Protection class |
I or II |
| Wind target area |
ca. 0.093 m² |
|